Linear position, rotary (angular) position, and tilt sensors by Everight Position, Positek, Netzer, Gill, Zettlex, and Posital
Distributed in North America by:
Everight Position Technologies Corporation
114 Forrest Avenue, Suite 110, Narberth, PA 19072
856-727-9500 or info@evrtp.com

Located outside North America? Click Here

High Performance Series

GYcRS Probe

High Performance Probe

GYcRS and GYcRP probe uses RS-422 differential line drivers signal transmission of which advantage is the noise free transmission with a simple interface. In combination with GYDC-05 controller, GYcRS probe has achieved high resolution of 1μm. GYcRP probe is available for high temperature ambient (200°C) and SRT (Shock Resistant Technology) options.

Specifications

Non-linearity < ±0.025%FS TYP
Resolution (Analog / Digital) 16bit (with GYHC) / Min.1μm (with DC05)
Repeatability < ±0.01%FS
Temperature Drift < ±20ppm FS/°C
Admissible Pressure 35MPa (Probe rod)
Operating Temperature -20°C-+80°C
Storage Temperature -40°C-+80°C
Vibration 6G (or 40Hz 2mmPP)
Shock 100G(2msec)
Protection IP65
Cable Length 1.5m (Standard) (Option Max.200m)

The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
Resolution depends on the controller combined.

Model No.

(1):Effective stroke
15mm-5200mm

(2):Thread
M:M24xP1.0 (Standard)
N:M18xP1.5
U:3/4-16UNF

(3):Sensor rod diameter
blank:Φ10 (Standard)
8:Φ8
14:Φ13.8

(4):Cable connection
CN:Connector (Standard)
G*:Pigtail type
(*:Cable length [m], Standard:1.5m)

Combined controller
Analogue output type:GYHC, GYFC2
Digital output type:GYDC-05
With LED Display:GKS-01 (only GYcRS)

Dimensions

Connector Type (Standard)

Pigtail Type (Option)

Material probe head:Al diecast, probe rod:SS304
(GYcRP probe) Standard magnet:No.2P Other magnets are available from Magnet Grouping [B].
(GYcRS probe) Standard magnet:No.2PN Other magnets are available from Magnet Grouping [GG].
The tip dead zone length (70mm) depends on the magnet or float type. Connector:Sanwa SNW-1607-PCF (Material:zinc alloy fluoroplastic)

In case of using probe only, probe outputs digital signals (start/stop) using RS422 differential line drivers.
In response to user's interrogation (start) pulse, probe provides stop pulse.

Everight Position Technologies Corporation | 114 Forrest Ave., Suite 110, Narberth, PA 19072 | 856-727-9500 or info@evrtp.com